LX 400 DGC Series Convoluted Diaphragm Gauge |
| |
Download the Product Broshure 
|
 |
 |
| |
|
|
| |
|
DP Range: 0-1 up to 0-25”H2O |
| COMBINATIONS |
|
|
| Gauge |
Specifications |
|
 |
Accuracy |
±2% of the FSD (Ascending) |
| Migration |
No migration ; Zero leakage from high to low port |
| Range |
0-1 to 0-25 inches H2O or similar ranges in other units |
| First marking on the scale |
15% of the FSD |
 |
Sensing element |
Diaphragm |
| Wetted parts |
Diaphragm, body material, 302 SS spring & ceramic magnet |
| Case material |
Engineered polymer |
| Dial size |
2.5”(square), 4.5” (round) |
| Mounting |
Line, front flange, 2” pipe & surface mounting |
|
Gauge+switch (with a DIN plug)
|
Maximum working pressure |
500 psi |
 |
Maximum process temperature |
175° F/80°C |
| Body material |
Aluminum & 316 SS |
| Seals |
Buna-N, Viton, EPDM diaphragm & ‘O’ rings |
| Window |
Plexiglass (acrylic) |
| Connection |
1/4” FNPT Std |
| Porting |
In-line, rear, bottom, bottom & vent, in-line & vent, in-line & bottom |
 |
Over range protection |
Up to MAWP from high side |
| Protection for gauge & switch |
NEMA-4X |
| |
|
| Options |
Switches (Adjustable in 40-100% of FSD) |
| Liquid filling |
1 or 2 SPSTs |
| MOUNTING BRACKETS |
Red follower pointer (except 6") |
1 SPDT |
 |
Customer logo |
Switch adjustment range 40-100% FSO |
| Dual scale |
|
| Colored Dial Arc |
|
| 1.6% Accuracy |
|
| |
|
 |
| |
| |
|